PNEUMATIC INLINE POWDER SAMPLER
JAM PROOF
BILL TO INFORMATION:
Email Address
First Name
Zip or Postal Code
Company
Telephone
Last Name
Street Address Line 1
Street Address Line 2
First Name
Zip or Postal Code
Company
Telephone
Last Name
Street Address Line 1
Street Address Line 2
QUOTATION /  INFORMATION REQUEST
WHITESTONE VA
TEL (804) 318-3686 FAX (703) 991-7133
[email protected] 
WWW.QCLABEQUIPMENT.COM
QTY                REF #               DESCRIPTION
Copyright 2012: QAQC Lab | Particle Measurement System | All rights reserved.
804-318-3686 | [email protected]
675 FG1000A      100 mm DIAMETER PIPE AUTOMATIC SAMPLER

675 FG1500A      150 mm DIAMETER PIPE AUTOMATIC SAMPLER

675 FG2000A      200 mm DIAMETER PIPE AUTOMATIC SAMPLER

675 FG3000A      300 mm DIAMETER PIPE AUTOMATIC SAMPLER
​MATERIALS OF CONSTRUCTION

Contact parts:    - 316 stainless steel
                              - PTFE
                              - Silicone rubber, Viton or EPDM
                              - Other materials on request

Non contact parts: - 304 grade stainless steel
                                  - Other materials as required.
The FreeGlide® is specially designed and engineered so that powder is kept out of the
bearings by a special flexible membrane - this means the sampler will not jam

The sample is collected in a cup and so is not physically altered by the sampling process

When the sampling cup is retracted the full bore of the downpipe is available for powder flow

The FreeGlide® is made from FDA acceptable materials and is easy to strip down for cleaning
INLINE POWDER SAMPLER
MANUAL OR AUTOMATIC OPERATION
PIPE DIAMETER 100mm to 300mm
675 FG (xxx m/a)
BROCHURE FREEGLIDE INLINE POWDER SAMPLER
EQUIPMENT FOR QUALITY CONTROL AND R&D 
www.qclabequipment.com
Telephone      (804) 318-3686
Toll Free US   (866) 244 1578
Fax                (703) 991-7133
Hours      8 AM - 6 PM EST
INTERNATIONAL & DOMESTIC SALES
CUSTOMER SERVICE * SALES * TECHNICAL SUPPORT


DELIVERIES WORLDWIDE

PERFORMANCE GUARANTEE
OPERATION

Resting
When the FreeGlide® is not in use the full bore of the downpipe is
available for powder flow.

Sampling
The sampling cup is extended into the downpipe to catch the
product as it falls.

Discharging
The sampling cup is then retracted and inverted. The powder
sample falls down the discharge chute to where it is collected
Recommended maintenance

In order to keep the sampler in good working order, regular maintenance is required
and this should be recorded and kept as a record.

All maintenance personnel who carry out the maintenance on the sampler should be fully qualified.

Recommended weekly maintenance

Visually inspect the Diaphragm for wear*
Visually inspect the Closing Plug for wear*
Visually inspect the Quadrings for wear*
Inspect filters for damage
Confirm that there is an earthing route from the cup to the Tee Piece (see section 5.3)
Confirm that there is an earthing route from the Tee Piece to the downpipe (see section 5.4)
Visually check that the sampler is making a good seal with the inside face of the product chute when 
in the extended and retracted positions.

* Polymer components must be viewed as consumable parts and replaced at the first signs of wear.

Lubrication schedule
There are no components on this sampler assembly which require lubrication.

5.3 Earthing (Grounding) Check – Inside Sampler
Ensure that the resistance between the cup and the Tee Piece is less than 1 Ohm.
The FreeGlide is fitted with phosphor bronze bearings; these provide a constant metal to metal earthing path 
through the equipment. There is no adjustment possible by the the customer. 

If the resistance is greater than 1 Ohm, then the inner workings of the sampler are electrically isolated. 
The device must not be reinstalled until it has been properly investigated. 

Earthing (Grounding) Check – to surrounding equipment
Ensure that the resistance between the Tee Piece and the Downpipe (i.e.
surrounding equipment) is less than 1 Ohm.
The automatic FreeGlide uses pneumatics to extend and retract the cup and to rotate it. Electrical sensors are used to monitor ® the position of the automatic FreeGlide .
MANUFACTURING
DISTRIBUTION
TECHNICAL SERVICES ​FOR
ANALYTICAL INSTRUMENTATION

TELEPHONE (804) 318-3686
TOLL FREE   (866) 244-1578

INSTALLING THE FRONT BOSS
ELECTRICAL CONNECTIONS
PRE ORDERING QUESTIONNAIRE
PRICING
SAMPLE MANUAL FOR AUTOMATIC FREEGLIDE
SAME AS BILL TO
NON VERTICAL INSTALL